-40%

TR-72nw Temperature / RH Data Logger with Cloud Storage-Wired LAN

$ 155.33

Availability: 100 in stock
  • Return shipping will be paid by: Buyer
  • All returns accepted: Returns Accepted
  • MPN: Does Not Apply
  • Condition: New
  • Restocking Fee: No
  • Brand: TandD
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Item must be returned within: 30 Days

    Description

    TR-72nw Temperature / RH Data Logger with Cloud Storage-Wired LAN
    The TandD TR-72nw is a temperature and RH data logger, but is available in a high precision model--TR-72nw-H. By using T&D WebStorage Service, a cloud service provided by T&D free of charge, it is possible to access stored data anytime from anywhere. Power Over Ethernet: PoE IEEE 802.3af (TR-72nw or TR-72nw-H only) Sensor Description Thermistor Polymer Resistance Measurement Channels Temperature 1ch Humidity 1ch Measurement Units °C, °F %RH Measurement Range Internal Sensor - - External Sensor 0 to 55°C 10 to 95%RH Accuracy ±0.5°C ±5%RH at 25°C, 50%RH Measurement Resolution 0.1°C 1%RH Responsiveness Response Time (90%): Approx. 7 min. LCD Display Items Measurements (fixed or alternating display), Battery Warning Mark, etc. Logging Capacity 8,000 data sets (One data set consists of readings for all channels in that type of unit.) Recording Interval Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min. Recording Mode Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full) Auto-upload Interval Select from 15 choices: OFF (No auto-upload), 1, 2, 5, 10, 15, 20, 30 min. or 1, 2, 3, 4, 6, 12, 24 hrs. Communication Interfaces Wireless LAN Communication TR-7wf Standard: IEEE 802.11b Security*1: WEP (64bit/128bit), WPA-PSK(TKIP), WPA2-PSK(AES) WPS 2.0: Push Button Configuration Protocol: HTTP*2, DHCP, DNS Wired LAN Communication TR-7nw 100BASE-TX/10BASE-T (RJ45 Connector) Protocol: HTTP*2, DHCP, DNS USB Communication TR-7wf/nw USB 2.0 Mini-B connector Power Battery: AA Alkaline × 2 (AA Ni-MH batteries may also be used) External: USB Bus (5V 200mA), AC Adaptor (AD-05A2 or AD-05C2), PoE IEEE 802.3af (TR-7nw only) Battery Life *3 With LAN communication: Approx. 10 days to 1.5 years *4Without LAN communication: Approx. 1.5 years Dimensions H 58mm × W 78mm × D 26mm Weight TR-7wf: Approx. 55 gTR-7nw: Approx. 65 g Operating Environment Temperature: -10 to 60°C *5 Humidity: 90%RH or less (no condensation) Accessories *6 Temperature-Humidity Sensor (THA-3001) × 1, AA Alkaline Battery (LR6) × 2, Registration Code Label, USB Mini-B Cable (US-15C), Manual Set (Warranty Included) Software PC Software: TR-7wf/nw for Windows, T&D Graph, T&D Data ServerMobile App: T&D Thermo Compatible OS*7 PC Software Microsoft Windows 10 32/64bitMicrosoft Windows 8 32/64bitMicrosoft Windows 7 32/64bit Microsoft Windows Vista 32 bit SP1 or later (T&D Data Server not compatible) Mobile App Android OS, iOS(For the compatible versions, please go to the app download page from here.) Display Languages *8 English *1: The WPS feature is not available when WEP(64bit/128bit) or WPA-PSK(TKIP) is selected in Access Point Settings. If you wish to use the WPS feature, please select WPA2-PSK(AES) or disable wireless security. *2: HTTP client. Proxy supported (for firmware version 1.05 or above for TR-7wf). *3: Battery life varies depending upon multiple factors including frequency of communication, LAN environment, ambient temperature, recording interval, and battery performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life. *4: Approx. 10 days when Auto-upload Interval is 1 min, 1 yr when 1 hr, 1.5 yrs when 12 hrs or more. *5: -10 to 45°C when using external power. (for TR-7nw) *6: Software is not included in the package, but can be downloaded free of charge from the download page. *7: For installation, it is necessary to have Administrator (Computer Administrator) rights. *8: We recommend using an operating system in the same language as the display language. Operation in different languages is not guaranteed.
    TR-72nw Temperature / RH Data Logger with Cloud Storage-Wired LAN
    The TandD TR-72nw is a temperature and RH data logger, but is available in a high precision model--TR-72nw-H.
    By using T&D WebStorage Service, a cloud service provided by T&D free of charge, it is possible to access stored data anytime from anywhere.
    Power Over Ethernet:  PoE IEEE 802.3af
    (TR-72nw or TR-72nw-H only)
    Sensor Description
    Thermistor
    Polymer Resistance
    Measurement Channels
    Temperature 1ch
    Humidity 1ch
    Measurement Units
    °C, °F
    %RH
    Measurement Range
    Internal Sensor
    -
    -
    External Sensor
    0 to 55°C
    10 to 95%RH
    Accuracy
    ±0.5°C
    ±5%RH
    at 25°C, 50%RH
    Measurement Resolution
    0.1°C
    1%RH
    Responsiveness
    Response Time (90%): Approx. 7 min.
    LCD Display Items
    Measurements (fixed or alternating display), Battery Warning Mark, etc.
    Logging Capacity
    8,000 data sets (One data set consists of readings for all channels in that type of unit.)
    Recording Interval
    Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.
    Recording Mode
    Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full)
    Auto-upload Interval
    Select from 15 choices: OFF (No auto-upload), 1, 2, 5, 10, 15, 20, 30 min. or 1, 2, 3, 4, 6, 12, 24 hrs.
    Communication Interfaces
    Wireless LAN Communication
    TR-7wf
    Standard: IEEE 802.11b
    Security
    *1
    : WEP (64bit/128bit), WPA-PSK(TKIP), WPA2-PSK(AES)
    WPS 2.0: Push Button Configuration
    Protocol: HTTP
    *2
    , DHCP, DNS
    Wired LAN Communication
    TR-7nw
    100BASE-TX/10BASE-T (RJ45 Connector)
    Protocol: HTTP
    *2
    , DHCP, DNS
    USB Communication
    TR-7wf/nw
    USB 2.0 Mini-B connector
    Power
    Battery: AA Alkaline × 2 (AA Ni-MH batteries may also be uséd)
    External: USB Bus (5V 200mA), AC Adaptor (AD-05A2 or AD-05C2),
    PoE IEEE 802.3af
    (TR-7nw only)
    Battery Life
    *3
    With LAN communication: Approx. 10 days to 1.5 years
    *4
    Without LAN communication: Approx. 1.5 years
    Dimensions
    H 58mm × W 78mm × D 26mm
    Weight
    TR-7wf
    : Approx. 55 g
    TR-7nw
    : Approx. 65 g
    Operating Environment
    Temperature: -10 to 60°C
    *5
    Humidity: 90%RH or less (no condensation)
    Accessories
    *6
    Temperature-Humidity Sensor (THA-3001) × 1, AA Alkaline Battery (LR6) × 2, Registration Code Label, USB Mini-B Cable (US-15C), Manual Set (Warranty Included)
    Software
    PC Software: TR-7wf/nw for Windows, T&D Graph, T&D Data Server
    Mobile App: T&D Thermo
    Compatible OS
    *7
    PC Software
    Microsoft Windows 10 32/64bit
    Microsoft Windows 8 32/64bit
    Microsoft Windows 7 32/64bit
    Microsoft Windows Vista 32 bit SP1 or later (T&D Data Server not compatible)
    Mobile App
    Android OS, iOS
    (For the compatible versions, please go to the app download page from
    here
    .)
    Display Languages
    *8
    English
    *1
    : The WPS feature is not available when WEP(64bit/128bit) or WPA-PSK(TKIP) is selected in Access Point Settings. If you wish to use the WPS feature, please select WPA2-PSK(AES) or disable wireless security.
    *2
    : HTTP client. Proxy supported (for firmware version 1.05 or above for
    TR-7wf
    ).
    *3
    : Battery life varies depending upon multiple factors including frequency of communication, LAN environment, ambient temperature, recording interval, and battery performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life.
    *4
    : Approx. 10 days when Auto-upload Interval is 1 min, 1 yr when 1 hr, 1.5 yrs when 12 hrs or more.
    *5
    : -10 to 45°C when using external power.
    (for TR-7nw)
    *6
    : Software is not included in the package, but can be downloaded free of charge from the
    download page
    .
    *7
    : For installation, it is necessary to have Administrator (Computer Administrator) rights.
    *8
    : We recommend using an operating system in the same language as the display language. Operation in different languages is not guaranteed.
    ×
    Buy now and save!
    Tell a friend
    Visit store
    Watch now
    Postage info
    Click the Postage tab above the listing description for more info
    Click the Postage tab above the listing description for more info!
    Additional delivery notes
    PICK UP OPTION
    Sorry, our items are NOT available for pick-up.
    PAYING VIA PAYPAL
    We accept PayPal on our all our items so you can shop with confidence.
    Simple choose the PayPal option when proceeding through the checkout.
    Additional Information
    No additional information at this time
    Ask seller a question
    You might also like
    1236-17 Thermometer
    1236-70 Espresso Thermometer
    1246-01 Pocket Test Thermometer
    1246-02 Pocket Test Thermometer
    Contact
    To contact our Customer Service Team, simply click the button here and our Customer Service team will be happy to assist.
    Ask seller a question
    © Tech Instrumentation
    Postage
    Click the Postage tab above the listing description for more info
    Payment
    Accepted Payment Methods
    PayPal
    Returns
    Returns are accepted
    Items must be returned within 30 days of the auction ending
    Buyer will pay for return shipping.
    eBay integration
    by