    TR-702 Network Connected Temp/Humidity Data Logger
    The network connected (Hardwired or Wireless) Temp/Humidity Data Logger TR-700W Series is a new type of temperature and humidity data logger equipped with a built-in function that enables connection to and use over the Internet or other network such as a LAN network. The downloading of recorded data, the monitoring of current readings and the sending of warning mails can all be done easily over the Internet or LAN network. The use of an Internet connection provides a low cost way to manage temperature and humidity data from long distances. The product is an all-in-one package that includes the data logger unit, sensors, cables and software. Specifications TR-701NW / 701AW TR-702NW / 702AW TR-702NW-H / 702AW-H Temperature/Humidity Sensor (External) TR-0106 THA-3151 HHA-3151(High-Precision Type) Thermistor Thermistor Polymer Resistance Platinum Resistance Electrostatic Capacitance Measurement Channels Temperature 2ch Temperature 1ch Humidity 1ch Temperature 1ch Humidity 1ch Measurement Units °C, °F °C, °F %RH °C, °F %RH Measurement Range -40 to 110 °C(Supplied Sensor)-60 to 155 °C(Optional Sensor: Fluoropolymer Coated Type) 0 to 55 °C 10 to 95%RH -30 to 80 °C 0 to 99%RH Accuracy Avg. ±0.3 °C [-20 to 80 °C] Avg. ±0.5 °C [-40 to -20 / 80 to 110 °C] ±0.5 °C ±5%RH [at 25 °C, 50%RH] ±0.3 °C [0 to 50 °C] ±0.5 °C [at all other temperatures] ±2.5%RH [at 25 °C, 10 to 85%RH] ±4.0%RH [at 25 °C, 0 to 10%RH or 85 to 99%RH]At temperatures other than 25 °C and ‰ۡÌ_å« 0 °C, add ±0.1%RH per degree of difference from 25.Humidity Hysteresis: ±1.5%RH or lower *1 Measurement Resolution 0.1 °C 0.1 °C 1%RH 0.1 °C 0.1%RH Responsiveness Thermal Time Constant: Approx. 75sec.Response Time (90%): Approx. 190sec. Response Time (90%): Approx. 7min. Response Time (90%): Approx. 7min. Response Time (90%): Approx. 20sec. Logging Capacity 8,000 data sets (One data set consists of readings for all channels in that type of unit.) Recording Interval Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min. Recording Mode Endless (Overwrite oldest data when capacity is full) LCD Display Items Measurements (alternating display), Power Warning Mark, etc. Communication Interfaces TR-701NW / 702NW: Wired LAN RJ45 Connector 100 Base-TX / 10 Base-T AutoMDI / MDI-XTR-701AW / 702AW: Wireless LAN Internal wireless LAN antenna IEEE 802.11b/g WEP‰ۢ_̦64bit/128bit‰ۢ_Ì_ / WPA-TKIP/WPA2-AESUSB Communication (For Setup) External Output Terminal Voltage when OFF: AC/DC less than 50V Current when ON: less than 0.1A Resistance when ON: about 35ÌÇå© Communications Protocol HTTP, SMTP (POP before SMTP, SMTP-AUTH ), FTP, SNTP, DHCP, DNS Power Main Power: AC Adaptor (AD-0638 or AD-0638-C) / Backup Power: Coin Type Lithium Battery (CR-2032) *2 Data Backup *3 Approx. 3 months (backup battery CR-2032 only without AC adaptor) Dimensions H 55 mm x W 78 mm x D 37 mm Weight TR-701NW / 702NW / 702NW-H : approx. 82 gTR-701AW / 702AW / 702AW-H : approx. 80 g (including battery, excluding sensor) Operating Environment Temperature: -10 to 60 °CHumidity: 90 %RH or less (no condensation) Accessories Temperature Sensor (TR-0106) x 2 Temperature/Humidity Sensor (THA-3151) x 1 High Precision Temperature/Humidity Sensor (HHA-3151) x 1 USB Communication Cable (US-15C), LAN Cable (LN-20W: For TR-701NW / 702NW only), AC Adaptor (AD-0638 or AD-0638-C), Coin Type Lithium Battery (CR-2032), Software (CD-ROM), Manual Set (Warranty Included) x 1 Software TR-700W for Windows Compatible Devices TR-701NW / 701AW, TR-702NW / 702AW, TR-702NW-H / 702AW-H Compatible OS*4 *5 Microsoft Windows 8 32/64 bit English Microsoft Windows 7 32/64 bit English Microsoft Windows Vista 32 bit (SP1 or later) EnglishMicrosoft Windows XP 32 bit (SP3 or later) English Supported Browsers Internet Explorer (6.0 or later), Firefox (15.0 or later), Chrome (22.0 or later), Safari (6.0 or later)Safari (iOS), Chrome (iOS, Android), Firefox (Android) *1: When used in environments where temperature and humidity are over the values of 50 °C 75%, 60 °C 50%, 70 °C 35%, and 80 °C 25%, sensor hysteresis may fluctuate by values greater than ±1.5%RH. Under certain circumstances, it may take some time to return to normal measurement capability. *2: The supplied lithium battery is for data backup during power failure and for emergency use only. Note that network communication cannot occur when using only the battery. *3: Battery life varies depending upon the ambient temperature and the battery performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life. *4: For installation, it is necessary to have Administrator (Computer Administrator) rights. *5: If you are using Windows 8, please note that our software is designed to be used in "Desktop" mode only.
    TR-702 Network Connected Temp/Humidity Data Logger
    The network connected (Hardwired or Wireless) Temp/Humidity Data Logger TR-700W Series is a new type of temperature and humidity data logger equipped with a built-in function that enables connection to and use over the Internet or other network such as a LAN network.
    The downloading of recorded data, the monitoring of current readings and the sending of warning mails can all be done easily over the Internet or LAN network. The use of an Internet connection provides a low cost way to manage temperature and humidity data from long distances.
    The product is an all-in-one package that includes the data logger unit, sensors, cables and software.
    Specifications
    TR-701NW / 701AW
    TR-702NW / 702AW
    TR-702NW-H / 702AW-H
    Temperature/Humidity Sensor (External)
    TR-0106
    THA-3151
    HHA-3151(High-Precision Type)
    Thermistor
    Thermistor
    Polymer Resistance
    Platinum Resistance
    Electrostatic Capacitance
    Measurement Channels
    Temperature 2ch
    Temperature 1ch
    Humidity 1ch
    Temperature 1ch
    Humidity 1ch
    Measurement Units
    °C, °F
    °C, °F
    %RH
    °C, °F
    %RH
    Measurement Range
    -40 to 110 °C(Supplied Sensor)
    -60 to 155 °C(Optional Sensor: Fluoropolymer Coated Type)
    0 to 55 °C
    10 to 95%RH
    -30 to 80 °C
    0 to 99%RH
    Accuracy
    Avg. ±0.3 °C [-20 to 80 °C] Avg. ±0.5 °C [-40 to -20 / 80 to 110 °C]
    ±0.5 °C
    ±5%RH [at 25 °C, 50%RH]
    ±0.3 °C [0 to 50 °C] ±0.5 °C [at all other temperatures]
    ±2.5%RH [at 25 °C, 10 to 85%RH] ±4.0%RH [at 25 °C, 0 to 10%RH or 85 to 99%RH]
    At temperatures other than 25 °C and ‰ۡÌ_å« 0 °C, add ±0.1%RH per degree of difference from 25.
    Humidity Hysteresis: ±1.5%RH or lower
    *1
    Measurement Resolution
    0.1 °C
    0.1 °C
    1%RH
    0.1 °C
    0.1%RH
    Responsiveness
    Thermal Time Constant: Approx. 75sec.
    Response Time (90%): Approx. 190sec.
    Response Time (90%): Approx. 7min.
    Response Time (90%): Approx. 7min.
    Response Time (90%): Approx. 20sec.
    Logging Capacity
    8,000 data sets (One data set consists of readings for all channels in that type of unit.)
    Recording Interval
    Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.
    Recording Mode
    Endless (Overwrite oldest data when capacity is full)
    LCD Display Items
    Measurements (alternating display), Power Warning Mark, etc.
    Communication Interfaces
    TR-701NW / 702NW: Wired LAN
    RJ45 Connector 100 Base-TX / 10 Base-T AutoMDI / MDI-X
    TR-701AW / 702AW: Wireless LAN
    Internal wireless LAN antenna IEEE 802.11b/g
    WEP‰ۢ_̦64bit/128bit‰ۢ_Ì_ / WPA-TKIP/WPA2-AES
    USB Communication (For Setup)
    External Output Terminal

    Voltage when OFF: AC/DC less than 50V
    Current when ON: less than 0.1A
    Resistance when ON: about 35ÌÇå©
    Communications Protocol
    HTTP, SMTP (POP before SMTP, SMTP-AUTH ), FTP, SNTP, DHCP, DNS
    Power
    Main Power: AC Adaptor (AD-0638 or AD-0638-C) / Backup Power: Coin Type Lithium Battery (CR-2032)
    *2
    Data Backup
    *3
    Approx. 3 months (backup battery CR-2032 only without AC adaptor)
    Dimensions
    H 55 mm x W 78 mm x D 37 mm
    Weight
    TR-701NW / 702NW / 702NW-H : approx. 82 g
    TR-701AW / 702AW / 702AW-H : approx. 80 g
    (including battery, excluding sensor)
    Operating Environment
    Temperature: -10 to 60 °C
    Humidity: 90 %RH or less (no condensation)
    Accessories
    Temperature Sensor (TR-0106) x 2
    Temperature/Humidity Sensor (THA-3151) x 1
    High Precision Temperature/Humidity Sensor (HHA-3151) x 1
    USB Communication Cable (US-15C), LAN Cable (LN-20W: For TR-701NW / 702NW only), AC Adaptor (AD-0638 or AD-0638-C), Coin Type Lithium Battery (CR-2032), Software (CD-ROM), Manual Set (Warranty Included) x 1
    Software
    TR-700W for Windows
    Compatible Devices
    TR-701NW / 701AW, TR-702NW / 702AW, TR-702NW-H / 702AW-H
    Compatible OS
    *4 *5
    Microsoft Windows 8 32/64 bit English
    Microsoft Windows 7 32/64 bit English
    Microsoft Windows Vista 32 bit (SP1 or later) English
    Microsoft Windows XP 32 bit (SP3 or later) English
    Supported Browsers

    Internet Explorer (6.0 or later), Firefox (15.0 or later), Chrome (22.0 or later), Safari (6.0 or later)

    Safari (iOS), Chrome (iOS, Android), Firefox (Android)
    *1:
    When uséd in environments where temperature and humidity are over the values of 50 °C 75%, 60 °C 50%, 70 °C 35%, and 80 °C 25%, sensor hysteresis may fluctuate by values greater than ±1.5%RH. Under certain circumstances, it may take some time to return to normal measurement capability.
    *2:
    The supplied lithium battery is for data backup during power failure and for emergency use only. Note that network communication cannot occur when using only the battery.
    *3:
    Battery life varies depending upon the ambient temperature and the battery performance. All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life.
    *4:
    For installation, it is necessary to have Administrator (Computer Administrator) rights.
    *5:
    If you are using Windows 8, please note that our software is designed to be uséd in "Desktop" mode only.
    ×
    Tell a friend
    Visit store
    Watch now
    Postage info
    Click the Postage tab above the listing description for more info
    Click the Postage tab above the listing description for more info!
    Additional delivery notes
    PICK UP OPTION
    Sorry, our items are NOT available for pick-up.
    PAYING VIA PAYPAL
    We accept PayPal on our all our items so you can shop with confidence.
    Simple choose the PayPal option when proceeding through the checkout.
    Additional Information
    No additional information at this time
    Ask seller a question
    You might also like
    1236-17 Thermometer
    1236-70 Espresso Thermometer
    1246-01 Pocket Test Thermometer
    1246-02 Pocket Test Thermometer
    Contact
    To contact our Customer Service Team, simply click the button here and our Customer Service team will be happy to assist.
    Ask seller a question
    © Tech Instrumentation
    Postage
    Click the Postage tab above the listing description for more info
    Payment
    Accepted Payment Methods
    PayPal
    Returns
    Returns are accepted
    Items must be returned within 30 days of the auction ending
    Buyer will pay for return shipping.
    eBay integration
    by