The LogTag® TRIX-8 data logger is a versatile, wide range, multi-trip Temperature Recorder, featuring high resolution temperature readings over a measurement range of -40°C to +85°C (-40°F to +185°F).
The LogTag® TRIX-8 calibrated temperature data logger is equipped with a unique external temperature sensor arrangement providing fast reaction time to temperature change. Protect the
TRIX-8 from damage with a
LogTag Protective Enclosure
for your data logger. Of course, we offer our temperature data logger calibration service for this and all of our data loggers.
IMPORTANT: Each location (not each logger) requires a LogTag Cradle in order to program and retrieve data from the logger. WE ARE CURRENTLY OUT OF STOCK OF THE LTI-HID CRADLE and the manufacturer does not anticipate stock availability until late April 2021. We have the LTI-WiFi cradle, and this is what you will receive, if you choose to add the cardle to your order.
Using the LogTag
®
Interface Cradle and the freely available companion software LogTag
®
Analyzer, the LogTag® TRIX-8 data logger is easily set-up for recording including delayed start, sampling interval, number of readings and configuration of conditions to activate the 'ALERT' indicator.
LogTag
®
Analyzer also provides facilities for charting, zooming, listing data statistics and allows exporting the data to other applications such as MS Excel once the data has been downloaded.
A real time clock provides date/time stamps for each temperature reading.
Push-to-start button with optional delay or a specific time & date. This portable temperature data logger comes with comprehensive customization options including alert settings, sample interval and trip duration. Complies with industry standards including EN12830. WHO PQS Prequalified under E006 devices : PQS Code E006/006
Highlights
Alert indicator
– indicates if readings are outside of preset limits
OK indicator
indicates if still recording and if readings within configured limits
Inspection mark
in log by push button
Push Button Logging start
Rapid Download!
Takes only seconds to download recordings
'Pre-Start' logging
- LogTag
®
can be configured to record even if it has not been started.
High performance
at low cost
Credit card sized case
– thin enough to be easily mailed “letter rate”.
Real time clock
records time & temperature simultaneously
Easy
to use LogTag
®
Analyze
r software that runs on any PC configures LogTag
®
for recording then downloads resulting data for analysis. Data can also be exported to formats compatible with other applications such as Excel
Highly reliable
and accurate
Re-calibration
is possible to achieve higher accuracy possible
Specifications
Model
Trix-8
Measurement Range
-40°C ~ +85°C (-40°F ~ +185°F)
Resolution
< 0.1°C for -40°C ~ +40°C,
< 0.2°C for +40°C ~+80°C
Accuracy
Better than ±0.5°C for -20°C~ +40°C.
Better than ±0.7°C for -20°C~ -30°C & +40°C~+60°C
Better than ±0.8°C for -30°C~ -40°C & +60°C~+80°C
Sensor Reaction Time
Typically less than 5 minutes(
T90
) in moving air (1m/s).
Capacity
8032 readings (16K bytes memory)
Sampling Frequency
Adjustable, 30 sec to several hours
Logging Start Options
Push button start or specific date & time. Optional start delay of up to 18hours.
Recording Indication
Flashing 'OK' indicator / flashing 'ALERT' indicator.
Download Time
Typically with full memory (8000 readings) in less than 5 secs depending on computer or readout device uséd.
Environmental
IP65 (roughly equivalent to NEMA 4)
Power Source
3V LiMg battery
Battery Life
2 ~ 3 years of normal use (based on 15 minute logging, download data monthly.
Size
86mm(H)x54.5mm(W)x8.6mm(T)
Weight
35g
Case Material
Polycarbonate
Other Features
• Logging start by push button or specific date/time start
• Optional clearing of alert indication by push button (places inspection make at same time).
• Download inspection mark recorded in LogTag memory every time LogTag is downloaded.
• 'Prestart' fail-safe logging (records temperature data even if not started)
• Low Battery indication in software.
• Comprehensive
Alert
indicator configuration.
• Calibration to achieve higher accuracy possible.
Cold-Chain Applications
Bacterial growth
Cool Chain Quality Indicator
(CCQI)
HACCP
Insulated shipping container
Logistics
Packaging
Shelf life
Specification
Temperature control
Time temperature indicator
Thermal decomposition
Thermal insulation
Tolerance (engineering)
Transportation management system
United States Pharmacopeia
Validation (drug manufacture)
Verification and validation
Calibration
In order to calibrate your LogTag Recorder, we use the LogTag Calibrate software. LogTag Recorders releases our LogTag Calibrate software only to selected users who have suitable equipment and credentials relating to standard practices of Temperature and/or Humidity calibration.
If you require calibration of your logger, please contact Tech Instrumentation at 303-841-7567 ext 2.
Calibrate after a battery change
Loggers that have had their case opened have potentially been exposed to electrostatic effects. In addition, units that had their battery replaced may not have been correctly hibernated or may have suffered from memory corruption if battery voltage was critically low during use.
They should therefore be validated for correct operation and performance after the
battery change
. The preferred way of doing this is by way of re-calibration, where ideally the product should be exposed to its full temperature measuring range.
Additional Info
Response Time for TRIX-8
The most common industry standard expression for temperature reading stabilization time is the ‘T90’. This is defined as the typical time taken of a given sensor in a given environment (e.g. moving air, still air, liquid etc.) to register 90% of an immediate step change in temperature.
The T90 of TRIX-8 is typically less than 5 minutes in moving air of 1m/s.
As the thermal step response is basically dependent on the latent heat of the two thermal masses involved (the Logger and the surrounding environment) and the rate of thermal transfer between them, the T90 is the same irrespective of the difference of temperatures though at extremes (water freezing and boiling points for example) the environment does not behave homogeneously thereby changing the rates of thermal conduction and therefore changing the resulting T90 value.
For example: in a situation of a 25°C step change say starting at 10°C and moving to 35°C in moving air of 1m/s, the TRIX-8 will typically register 90% of the step after less than 5 minutes – i.e. 0.9×25 = 22.5 -> 10+22.5 = registering 32.5°C within 5mins.
The T90 for a 15°C step in 1 m/s moving air (say 10°C to 25°C) will be the same. 0.9×15 = 13.5°C +10 = registering 23.5°C within 5mins.
T90 is different in slower moving air or still air, though air is never totally ‘still’ when a temperature difference exists as convection will take place.
×
×
×
Tell a friend
Visit store
Watch now
Postage info
Click the Postage tab above the listing description for more info
Click the Postage tab above the listing description for more info!
Additional delivery notes
PICK UP OPTION
Sorry, our items are NOT available for pick-up.
PAYING VIA PAYPAL
We accept PayPal on our all our items so you can shop with confidence.
Simple choose the PayPal option when proceeding through the checkout.
Additional Information
No additional information at this time
Ask seller a question
You might also like
1236-17 Thermometer
1236-70 Espresso Thermometer
1246-01 Pocket Test Thermometer
1246-02 Pocket Test Thermometer
Contact
To contact our Customer Service Team, simply click the button here and our Customer Service team will be happy to assist.
Ask seller a question
© Tech Instrumentation
Postage
Click the Postage tab above the listing description for more info
Payment
Accepted Payment Methods
PayPal
Returns
Returns are accepted
Items must be returned within 30 days of the auction ending
Buyer will pay for return shipping.
eBay integration
by