    General Specifications
    Channel Capacity
    Analog Inputs:
    21; Digital I/O & Alarm Outputs
    Totalizer:
    1
    Power, battery life
    90V ac to 264V ac (50 Hz or 60 Hz), or 9V dc to 16V dc; less than 10W. (If both sources are applied simultaneously, the greater of ac or dc is used. At 120V ac the equivalent dc voltage is ~14.5V)
    Temperature, Humidity (non-condensing)
    Operating:
    0 to 28ºC, <=90% RH; 28ºC to 40ºC, <=75% RH; 40ºC to 60ºC, <=50% RH; Storage: -40ºC to 75ºC, 5 to 95% RH
    Altitude
    Operating:
    3050m (10,000 ft);
    Storage:
    12,200m (40,000 ft)
    Common Mode and Normal Mode Voltage
    300V dc or ac rms (channels 0,1,11); 25%V dc or ac rms (all other channels) IEC Overvoltage Category II.
    Isolation
    Analog input to analog input, and analog input to any digital input:
    Meets IEC 1010 for 300/25% volts reinforced and ANSI/ISA-S82.01-1988 and CSA 231 for 250 volts single insulation
    Safety
    Complies with applicable sections of the IEC1010, ANSI/ISA-S82.01-1988, CSA231, UL 1244, CSA 556B, CE.
    RF Emissions
    Passes FCC EMI Class A Equipment and VDE 0871B
    Size
    9.3 cm x 21.6 cm x 31.2 cm (3.67" x 8.50" x 12.28")
    Weight
    2.95 kg (6.5 lb)
    Memory life
    10 years typical for real-time clock, set-up configuration and measurement data in 2625A, memory cards typically 5 years for the 256 kB card
    Interfaces
    RS-232C connector: nine pin male (DB-9P)
    Signals
    TX, RX, DTR, GND
    Modem Control
    Full duplex
    Baud Rates (Set from front panel)
    300, 600, 1200, 2400, 4800, 9600, 19.2k, 38.4k
    Echo (Set from front panel)
    On/Off
    Flow Control
    XON/XOFF
    Technical Specifications
    DC Volts
    Range:
    90 mV to 300/25%V
    Resolution:
    1 µV to 10 mV
    Accuracy:
    (3-Sigma)± 0.018%
    AC Volts
    Range:
    90 mV to 300/25%V
    Resolution:
    1 µV to 10 mV
    Accuracy:
    (3-Sigma)± 0.018%
    Resistance
    Range:
    300Ω to 10 MΩ
    Resolution:
    10 mΩ to 1 KΩ
    Accuracy:
    (3-Sigma)± 0.013%
    Frequency
    Range:
    15 Hz to 1 MHz
    Resolution:
    0.01 Hz to 1 kHz
    Accuracy:
    (3-Sigma)± 0.05%
    RTD (Pt 100)
    Range:
    -200 to 600ºC
    Resolution:
    0.02ºC
    Accuracy:
    (3-Sigma)± 0.05ºC
    J Thermocouples
    Range:
    -100 to 760ºC
    Resolution:
    0.1ºC
    Accuracy:
    (3-Sigma)± 0.39ºC
    K Thermocouples
    Range:
    -100 to 1372ºC
    Resolution:
    0.1ºC
    Accuracy:
    (3-Sigma)± 0.45ºC
    T Thermocouples
    Range:
    -25% to 400ºC
    Resolution:
    0.1ºC
    Accuracy:
    (3-Sigma)± 0.39ºC
    Other
    Thermocouple types
    R, S, B, C, E, N