    Fluke 1750 Three-Phase Power Quality Recorder
    Once power is applied the instrument automatically begins recording and LEDs give you assurance that the recorder is powered up and signals are within range – no more uncertainty that data is being recorded
    Every cycle on every channel is simultaneously sampled providing complete analysis of power quality, harmonics, power and energy
    Includes Hard Carrying Case & Accessories As Listed Above!
    Working Condition: Excellent
    Condition: Refurbished
    Calibrated: Yes
    Warranty: 1 YEAR WARRANTY
    Fluke 1750 Three-Phase Power Recorder
    Capture every measurement, every event, on every cycle, all the time with the Fluke 1750 Power Recorder. Outstanding accuracy and resolution provide complete visibility into your installation or distribution system.
    Easy to use
    The recorder automatically detects, scales, and powers current probes without needing batteries. Requiring only single-lead voltage connections enables safe and quick setups. Once power is applied the instrument automatically begins recording and LEDs give you assurance that the recorder is powered up and signals are within range – no more uncertainty that data is being recorded. The Fluke 1750 has an exclusive capture algorithm which makes certain all events are captured without the tedious setups and blind spots associated with threshold driven equipment. The PDA wirelessly interfaces with the recorder, allowing quick setup and verification with waveform displays, meter screens, and phasor diagrams. The built-in wireless technology allows you to control multiple instruments from a distance easily, without the need for a laptop computer (laptops can also be used when desired).
    Comprehensive power system data
    Every cycle on every channel is simultaneously sampled providing complete analysis of power quality, harmonics, power and energy. Cross channel current and voltage triggering captures event data on all input channels simultaneously, no matter which channel triggered the event. When periodic analysis of the waveform may be needed, the Snapshot mode captures waveforms at user defined intervals. Even dc signals can be recorded!
    Powerful data management
    Data is automatically stored on the internal flash memory that can store records for over a month without compression or overwriting. Data is retrieved via one of two quick and easy options: download the data onto the SD memory card without using your laptop, or transfer directly to your computer via Ethernet, using TCP/IP protocol.Voice, data, and picture annotations can be made via the PDA to flag important points in the data stream. Imagine being able to flag in your recorded data when a transfer switch was operated, or load changes were made.
    View data the way you want
    The new Fluke Power Analyze software revolutionizes your ability to analyze data. No need to worry about thresholds—with Fluke Power Analyze, thresholds can be modified after the data is recorded! And the easy-to-use user interface will display voltage as a phase-to-phase or phase-to-neutral reading.
    All the latest power quality standards are built-in
    IEC 61000-4-30 compliant measurement systems provide the confidence that all parameters are measured and calculated consistently with international standards. Automated EN50160 compliance reporting for rapid Pass/Fail testing.
    600 V CAT IV and 1000 V CAT III safety rating
    Designed to help protect you and your equipment, the Fluke 1750 Three-Phase Power Recorder and accessories are all certified to meet the stringent safety standards for use in 600 V CAT IV and 1000 V CAT III environments. They are the first tools of their kind to carry the CAT IV rating and, therefore, can be used for most power connections and for all outlets in a low-voltage power distribution system.
    Applications:
    Long-term analysis:
    Uncover hard-to-find or intermittent issues; monitor critical equipment, capturing power quality events to correlate with equipment malfunction
    Power quality surveys:
    Quantify power quality throughout a facility, documenting results with professional reports
    Quality of service compliance:
    Validate incoming power quality at the service entrance
    Equipment Installation/Commissioning:
    Benchmark power system prior to install to insure quality of service
    Features:
    Power quality that meets the standard:
    All measurements comply with IEC61000-4-30 standards for correct evaluation of all measured values including voltage, current, power, harmonics, flicker etc.
    Quick and reliable configuration:
    PDA wireless “front panel interface” provides the ability to verify setup without a laptop along with a window into what the instrument is recording, even in awkward test locations.
    Threshold-free setup:
    Apply thresholds after data is collected with Fluke Power Analyze Software so there is no need to worry about missed information due to incorrect set-up.
    Captures everything:
    Cross-channel and current triggering capture every measurement, on every channel, every time.
    Intuitive PC software:
    Easily analyze data and generate reports. Automated EN50160 reporting and compliance.
    Plug and play:
    Set up in minutes with self identifying current probes and single-lead voltage connections.
    No need to reconnect wires:
    Swap channels internally with the wireless PDA or PC when connections are not correct.
    Measure every parameter:
    voltage and current on three phases, neutral, and ground
    5 MHz, 8000 Vpk waveform capture:
    Get a detailed picture of even the shortest events.
    Specifications:
    General
    Power quality measurement standards
    Conformance
    IEC 61999-1-4 Class 1, IEC 61000-4-30, IEEE519, IEEE1159, IEEE1459 and EN50160
    Clock/calendar
    Leap years, 24-hour clock
    Real-time clock accuracy
    Not more than ± 1 s/day
    Internal memory capacity for data
    At least 2 GB
    Maximum recording period
    At least 31 days
    Measurement time control
    Automatic
    Maximum number of events
    Limited only by the size of the internal memory
    Power requirements
    100 to 240 V rms ± 10 %, 47-63 Hz, 40 W
    Operating time during interruptions
    (internal UPS operation)
    5 minutes per interruption, 60 minutes total operating time without recharging
    Dimensions
    215 mm x 310 mm x 35 mm (8.5 in x 12.2 in x 3.5 in)
    Mass (weight)
    6.3 kg (14 lb)
    Input
    Measurement types
    One Phase Plus Neutral, One Phase IT No Neutral, One Phase Split Phase, Three Phase Wye,
    Three Phase Delta, Three Phase IT, Three Phase High Leg, Three Phase Open Leg, 2 Element Delta,
    2 1/2 Element Wye
    Input channels
    Voltage: 4 channels, ac/dc
    Current: 5 channels
    Voltage channels
    Input resistance: 2 MΩ
    Input capacitance: < 20 pF
    Current input characteristics
    2 V rms = full scale, 1 MΩ Input Impedance for ferro CTs, low impedance for Flexi-CTs
    Measuring method
    Simultaneous digital sampling of voltage and current. Digital PLL synchronized sampling, internal
    frequency reference used during voltage drops.
    Synchronization and sampling
    PLL-synchronization source
    The PLL synchronizes to the A-N voltage for wye power types, and to the A-B voltage for delta
    power types. All listed power types can be characterized as either wye or delta.
    PLL lock range
    42.5 to 69 Hz
    Sampling frequency
    Voltage and current: 256 samples/cycle
    Inter-harmonics per IEC 61000-4-7: 2560 points/10 cycles (50 Hz),
    3072 points/12 cycles (60 Hz)
    Transient Voltage: 5 MHz
    A/D resolution
    Voltage and current: 24 bits
    Transient voltage: 14 bits
    Voltage and current measurements
    Voltage measurement range
    AC voltage: 1000 V rms ± 10 % over range
    DC voltage: ± 1000 V + 10 % over range
    Voltage crest factor
    3 or less
    Current measurement range
    Depends on current probe used
    Current crest factor
    4 or less
    Voltage and current measurement accuracy
    RMS voltageEN 61010-1 2nd Edition; 2000
    Voltage input unit: Contamination Level 2, Overvoltage Category 1000 V CAT III, 600 V CAT IV
    (anticipated overvoltage: 8000 V)
    Measurement type
    True rms calculated continuously: every cycle, every 1/2 cycle, and
    every 10 or 12 cycles at 50 or 60 Hz respectively, as required by IEC 61000-4-30
    Measurement uncertainty
    AC: ± 0.2 % reading ± 0.1 % full scale, above 50 V rms
    DC: ± 0.5 % reading ± 0.2 % full scale, above 50 V dc
    RMS current
    Measurement type
    True rms calculated continuously: every cycle, every 1/2 cycle, and
    every 10 or 12 cycles at 50 or 60 Hz respectively, as required by standards
    Measurement uncertainty
    Ferromagnetic Clamps: ± (0.1 % full scale + 0.2 % reading + current sensor accuracy),
    valid for 5 % to 100 % of current sensor range
    Flexible Current Probes: ± (0.1 % full scale + 0.5 % reading + current sensor accuracy),
    valid for 5 % to 100 % of current sensor range
    Transient voltage (impulse)
    Measurement type
    Waveshape sampling
    Full scale
    8000 V pk
    Sample resolution
    200 nS
    Measurement uncertainty
    ± 5 % reading ± 20 V (test parameters: 1000 V dc, 1000 V rms, 100 kHz)EN 61010-1 2nd Edition; 2000
    Voltage input unit: Contamination Level 2, Overvoltage Category 1000 V CAT III, 600 V CAT IV
    (anticipated overvoltage: 8000 V)
    Dip (Sag) and Swell Measurements
    Voltage swell (rms swell)
    Measurement type
    True rms (one cycle calculation by overlapping each half cycle - voltage between lines is measured
    for 3P3W lines and phase voltage is measured for 3P4W lines)
    Displayed data
    Amplitude and duration of swell
    Measurement uncertainty
    Same as rms voltage
    Voltage dip (rms sag)
    Measurement type
    True rms (one cycle calculation by overlapping each half cycle - voltage between lines is measured
    for 3P3W lines and phase voltage is measured for 3P4W lines)
    Displayed data
    Amplitude and duration of dip or interruption
    Measurement uncertainty
    Same as rms voltage
    Voltage dropout (interruption)
    Measurement type
    Same as voltage dip
    Power Measurements
    Calculated per IEEE1459 for best performance when distortion is present
    Measurement type
    True rms calculated continuously: every cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by standards
    Measurement accuracy
    +/- (voltage uncertainty + current uncertainty + current probe uncertainty)
    Frequency
    Measurement range
    42.5 to 69 Hz
    Measurement source
    Same as PLL synchronization source
    Measurement accuracy
    ± 10 mHz (10 to 110 % of range, with sine wave)
    Power factor
    Measurement range
    0.000 to 1.000
    Measurement accuracy
    ± 1 digit from the calculation of each measured value (±3 digits for total)
    Displacement power factor
    Measurement method
    Calculated from the phase difference between voltage fundamental and current fundamental
    Measurement range
    - 1.000 (leading) to + 1.000 (lagging)
    Measurement accuracy
    ± 0.5 % reading ± 2 % full scale ± 1 digit
    Voltage unbalance and phase sequence
    Measurement method
    Positive sequence voltage divided by negative sequence voltage, per IEC 61000-4-30
    Harmonic voltage and current
    Analysis window
    rectangular
    Analysis order
    1st to 50th order
    Measurement accuracy
    Voltage / Current: 1st to 20th orders: ± 0.5 % reading ± 0.2 % full scale, 21st to 50th orders: ± 1 %
    reading ± 0.3 % full scale (current sensor accuracy must be included for current and power)
    Measurement method
    IEC 61000-4-7
    Inter-harmonic voltage and current (intermediate harmonics)
    Analysis window
    rectangular
    Analysis orders
    1.5 to 49.5th order
    Measurement method
    IEC 61000-4-7
    Voltage flicker
    Measurement method
    as per EN 61000-4-15:2003: 10 min (Pst), 2 h (Plt)
    External Interface Specifications
    LAN interface
    Connector
    RJ-45
    Speed and type
    10/100 Base-T, auto MDIX
    Communications protocol
    TCP/IP over Ethernet
    Wireless controller interface
    Connection
    wireless (2.4 GHz radio)
    Speed
    up to 700 kbit/second
    Communications protocol
    Bluetooth SPP
    Environmental and safety specifications
    Operating environment
    Indoors or in covered area outdoors, up to 2000 m altitude (for compliance to IEC61010 standard)
    Storage temperature and humidity
    -20 °C to 50 °C, 80 % RH max, non-condensing
    Operating temperature and humidity
    0 °C to 40 °C, 80 % RH max, non-condensing
    Maximum rated working voltage
    Voltage terminals
    1100 V rms
    Voltage durability
    5550 V rms ac for 1 minute, between voltage input terminals, voltage input terminals and current probes, and voltage input terminals and case (50/60 Hz, 1 mA sense current)
    Enclosure protection
    IP30 (per EN 60529)
    Standards conformance
    EMC
    EN 61326-1:1997+A1:1998 Class A
    EN 61000-3-2:1995+A1:1998+A2:1998
    EN 61000-3-3:1995
    Safety
    EN 61010-1 2nd Edition; 2000
    Voltage input unit: Contamination Level 2, Overvoltage Category 1000 V CAT III, 600 V CAT IV
    (anticipated overvoltage: 8000 V)
    For full Fluke 1750 product specifications, please click here:
    Fluke 1750
    Please check our Huge Inventory with savings of up to 80% off of retail on Cat5/5e/6 LAN Cable Certifiers and Fiber Optic OTDR's, Fusion Splicers, CATV Meters, Fiber Optic Kits, Sources, Meters, Tools, Network Analyzers and much more. Here is a Link to our
    Ebay Test Equipment Store
    . All of our Test Equipment is backed with a Full Warranty and unbeatable customer support & service. Please don't hesitate to
    contact us
    for a Quote on Something you don't see in our inventory, sometimes we have items that may have not been listed or processed yet.
    Test Equipment Store Offers a wide range of Refurbished Telecom/ Datacom Tools and Test Measurement Equipment. Which includes Fiber Optic Test and Splicing tools, Fusion Splicers, OTDRs, Copper and Fiber Cable Certifiers, CATV Test Equipment, Cable and Antenna Analyzers, Network Analyzers and much more!
    We carry a large inventory of quality refurbished and used test equipment from all the major manufacturers. If you are looking for multiple quantities or if we don't have a listing for a particular item that you are looking for. Please contact us as it may be fresh inventory waiting to be listed or we'll be glad to find it for you at the best price possible and put up an eBay listing for you!
    We Ship World Wide!
    We will attempt to ship your item(s) within 24 hours after payment has been received. To get a real-time shipping quote to your destination, enter your country and zip / postal code information into the shipping calculator and click "Get Rate".
    Many countries impose their own customs, duties, tariffs, taxes, etc. on items being shipped from a foreign country. We do not cover those cost's and we recommend that you contact your countries customs agency for that information.
    We Offer Multiple Quantity Price & Shipping Discounts, Email Us If You Are Interested In Larger Quantities.
    We accept credit card payment transactions via the online checkout system! The checkout process is designed so that it communicates with the merchant to confirm that payment has been made and cleared. Other methods of payment are outlined through the online checkout process. Winning bidders must contact us within 3 days after auction close if special payment arrangements are needed.
    Your payment is expected within 5 days after the auction close. Unpaid auctions will be forfeited after 5 days of the auction close and the Item(s) will be relisted for sale.
    Items will be shipped within 24 hours (1 Business Day) upon receipt of payment from the winning bidder. (Certain orders may take longer for processing due to comprehensive final service inspections)
    A Shipment Tracking number(s) will be provided to inform Buyers of their expected ETA (Estimated Time of Arrival). Tracking number(s) will be provided the same day as order shipment.
    Thank you
    ALL MAJOR CREDIT CARDS & PayPal ACCEPTED
    Sell Smarter with
    Kyozou
    .
    Inventory and Ecommerce Management