-40%

Campbell Scientific SDM-SW8A 8-channel switch closure input module - Warranty

$ 105.07

Availability: 100 in stock
  • Brand: Campbell Scientific
  • MPN: SDM-SW8A
  • Condition: Excellent condition with warranty.
  • Item must be returned within: 30 Days
  • Return shipping will be paid by: Buyer
  • Restocking Fee: 20%
  • All returns accepted: Returns Accepted
  • Model: SDMSW8A
  • Refund will be given as: Money back or replacement (buyer's choice)

    Description

    SDM-SW8A 8-channel  switch closure input  module - Great shape Warranty
    This sale is for a
    :
    SDM-SW8A 8-channel  switch closure input  module - Great shape Warranty
    Condition:
    Used, excellent shape.
    Warranty:
    30 Day Warranty.
    We pledge to offer the best service and warranty to all of our customers!  We are extending a 30 Day warranty on this item.  This is our way of saying thank you for allowing us to serve you.
    Certification:
    This is an genuine product from this manufacturer.
    Web Information:
    Detailed Description
    The SDM-SW8A provides eight channels for connecting the sensors. Each channel is individually configured for single-pole double-throw (SPDT), single-pole single-throw (SPST), or voltage pulse measurements. Output options include counts, duty cycle, and state.
    SDM Operation
    The data logger enables individual modules through an addressing scheme; multiple SDMs (in any combination) can be connected to one data logger. We recommend a maximum of four SDM-SW8As be connected to a single data logger. After a module is enabled, it operates independently of the data logger until additional commands are received or results are transmitted.
    Specifications
    Measurement Types
    Switch closure (SPDT, SPST), dc voltage pulse
    Input Voltage Threshold
    From below 0.9 to above 4.0 Vdc (±20 Vdc maximum)
    Maximum Input Frequency
    100 Hz (50% duty cycle)
    Minimum Input Pulse Width
    5 ms high, 5 ms low
    Maximum Bounce Time
    3 ms open without counting
    Output Options
    State, duty cycle, counts
    Maximum Count/Port
    65535
    Internal Sampling Frequency
    500 Hz
    Watchdog Reset
    Yes
    Operating Temperature Range
    -25° to +55°C
    Operating Voltage Range
    9.6 to 16 V
    Typical Current Drain
    3 mA quiescent
    6 mA active (maximum)
    Relative Humidity
    0 to 90% RH (non-condensing)
    Maximum Cable Length
    6 m (20 ft) total to all SDM devices
    Consult Campbell Scientific if longer lengths are necessary.
    Dimensions
    15.7 x 6.9 x 2.3 cm (6.2 x 2.7 x 0.9 in.)
    Weight
    0.23 kg (0.5 lb)